QUYI JAG‘ SUYAGI SINIQLARIDA TITANIUM MINIPLASTINKA OSTEOSINTEZI VA BIOREABSORBIROVANILANADIGAN KONSTRUKTSIYALAR BILAN BARQARORLASHTIRISH NATIJALARI BO‘YICHA RETROSPEKTIV TAHLIL
Keywords:
quyi jag‘ sinig‘i, osteosintez, titanium miniplastinka, bioreabsorbirovanilanadigan implantlar, yuz-jag‘ jarrohligi, retrospektiv tahlil, ortopantomografiya, suyak regeneratsiyasi.Abstract
Quyi jag‘ suyagi siniqlari yuz-jag‘ jarrohligida eng ko‘p uchraydigan travmatik shikastlanishlardan biri hisoblanadi. Bunday holatlarda anatomik yaxlitlikni tiklash, chaynash funksiyasini qayta tiklash va asoratlarning oldini olish maqsadida osteosintez usullari keng qo‘llaniladi. Mazkur retrospektiv kohort tadqiqotda 2018–2024-yillar davomida yuz-jag‘ jarrohligi bo‘limida davolangan 140 nafar bemorning davolash natijalari o‘rganildi. Bemorlarning 70 nafari titanium miniplastinkalar yordamida, 70 nafari esa bioreabsorbirovanilanadigan plastinka va vintlar yordamida operatsiya qilingan. Tadqiqot davomida rentgenologik suyak birlashuvi, infeksion asoratlar, implant turg‘unligi, qayta operatsiya ehtiyoji hamda funksional tiklanish ko‘rsatkichlari retrospektiv ravishda baholandi. Olingan natijalar titanium va bioresorblanuvchi osteosintez tizimlarining afzalliklari hamda cheklovlarini aniqlash imkonini berdi.
References
1.Fonseca RJ, Walker RV, Betts NJ, Barber HD. Oral and Maxillofacial Trauma. 5th ed. St. Louis: Elsevier; 2020.
2.Miloro M, Ghali GE, Larsen PE, Waite PD. Peterson's Principles of Oral and Maxillofacial Surgery. 4th ed. Shelton: PMPH-USA; 2022.
3.Ellis E III, Graham J. Use of a 2.0-mm locking plate/screw system for mandibular fracture surgery. Journal of Oral and Maxillofacial Surgery. 2002;60(6):642–645.
4.Champy M, Lodde JP, Schmitt R, Jaeger JH, Muster D. Mandibular osteosynthesis according to the Michelet technique. Journal of Maxillofacial Surgery. 1978;6(1):14–21.
5.Gear AJL, Apasova E, Schmitz JP, Schubert W. Treatment modalities for mandibular angle fractures. Journal of Oral and Maxillofacial Surgery. 2005;63(5):655–663.
6.Böstman O, Pihlajamäki H. Clinical biocompatibility of biodegradable orthopaedic implants. Biomaterials. 2000;21(24):2615–2621.
7.Eppley BL, Morales L, Wood R, Pensler J, Goldstein J, Havlik RJ, et al. Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery. Journal of Craniofacial Surgery. 2004;15(4):547–553.
8.Turvey TA, Proffit WR, Phillips C. Biodegradable fixation for craniomaxillofacial surgery. International Journal of Oral and Maxillofacial Surgery. 2011;40(7):659–667.
9.Laughlin RM, Block MS, Wilk R, Malloy RB, Kent JN. Resorbable plates for the fixation of mandibular fractures. Journal of Oral and Maxillofacial Surgery. 2007;65(1):89–96.
10.Sukegawa S, Kanno T, Shibata A, Matsumoto K, Sukegawa-Takahashi Y, Furuki Y. Use of bioresorbable plates in mandibular fracture fixation: systematic review. Journal of Cranio-Maxillofacial Surgery. 2019;47(9):1397–1403.